Fronius Status Codes

All Fronius status codes, what they mean & how to fix them!

Below is a list of the various codes that may appear on your Fronius inverter. We recommend restarting your inverter if any issues do arise. 

Just like restarting your computer, restarting your inverter can fix some common issues.

How do I restart my inverter?

These common issues include: 

  • Faults and errors that are displayed on the inverter (take note of these before restarting your inverter in case the error continues). These may relate to external factors like grid voltage or wiring
  • The system not communicating with internet monitoring (you may also need to restart your modem)
  • If the system is generally not performing as it should

In the event that restarting your inverter doesn’t work, here is a list of what to do in the event of each Fronius status code.

 

1 XX Fronius Inverter Error Codes
Code Meaning What To Do? 
#102 The AC voltage is too high Contact your GEM Energy 1300 969 471.
#103 The AC voltage is too low
#105 The AC frequency is too high
#106 The AC frequency is too low
#107 The AC grid outside the allowed limits
#108 Independent operation detected
#112 A residential current monitoring unit (RCMU) error has occurred
#141 Grid frequency has jumped too high This value can be adjusted to the grid via menupoint RoCoF (Rate of Change of Frequency) in the Menu. Alternatively, contact GEM Energy
3 XX Fronius Inverter Error Codes
Code Meaning What To Do?
#301 Excess AC current The fault will fix itself. If the fault keeps appearing, contact GEM Energy.
#302 Excess DC current
#303 DC module overheating
#304 AC module overheating
#305 Power is not being fed in, although the relay is closed
#306 The PV output is too low to feed The fault will fix itself. If the fault keeps appearing even insufficient sunlight, contact GEM Energy
#307 The PV output is too low to feed Contact GEM Energy
#308 The intermediate circuit voltage is too high The fault will fix itself. If the fault keeps appearing, contact GEM energy
#309 The DC input voltage MPPT (maximum power point tracker is too high)
#311 The polarity of the DC strings reversed.  The fault will fix itself. If the fault keeps appearing, contact GEM Energy
#313 The DC input voltage MPPT (maximum power point tracker) 2 is too high.
#314 Current sensor calibration timeout
#315 AC current sensor error Contact GEM Energy 1300 969 471
#316 Interrupt check fail
#317 Unbalanced intermediate circuit voltage
#318 DC bank current detected
#325 Connection area overheating
#326 Error with fan 1 
#327 Error with fan 2
4 XX Fronius Inverter Error Codes
Code Meaning What To Do? 
#401 The AC voltage is too high Contact GEM Energy 1300 969 471
#406 Temperature sensor for AC module is faulty (1)
#407 Temperature sensor for DC module is faulty (L2)
#408 DC component measured in the grind is too high
#412 Fixed voltage mode has selected instead of MPP voltage mode and the fixed voltage mode has been set at the wrong value. If this code continues to appear, contact GEM Energy
#415 Safety cut out has triggered via option card or RECERBO Contact GEM Energy 1300 969 471
#416 Power stage set has no communication with control system
#417 Hardware ID issue Contact GEM Energy
#419 Unique ID issue
#420 Unable to communicate with hybrid manager
#421 HID ranger error
#425 Unable to communicate with power stage set
#426, #427, #428 Hardware fault
#431 Software fault Conduct an AC reset (switch it off and on); update inverter firmware, if the fault continues to appear, contact GEM Energy
#436 Functional incompatibility Contact GEM Energy 1300 969 471
#437 Power stage fault
#438 Functional incompatibility
#443 The intermediate circuit voltage is too low or asymmetric
#445 Compatibility fault – invalid power stage set configuration
#447 Insulation problem If the fault continues to appear, contact GEM Energy
#448 The neutral conductor is not connected.
#450 The guard can’t be found If the fault continues to appear, contact GEM Energy
#451 Memory fault detected
#452 Communication problem between processors
#453 Power stage set and grid voltage are not compatible 
#454 Power stage and grid frequency are not compatible
#456 Anti-islanding function is no longer implemented correctly
#457 The grid relay sticking or the neutral conductor ground voltage is too high
#458 Issues when recording measuring signal. Contact GEM Energy 1300 969 471
#459 Issues when recording the measuring signal for insulation test.
#460 Reference voltage source for the DSP (digital signal processor) is working out of tolerance
#461 Error in the DSP (digital signal processor) data memory 
#462 Fault with the DC feed monitoring routine
#463 Reversed AC polarity, The AC connector has been incorrect;y inserted
#474 The RCMU sensor is faulty
#475 Insulation fault (the connection between the solar panel and the ground is faulty) 
#476 The driver supply voltage is too low
#479 Intermediate circuit relay has switched off
#480, #481 Functional incompatibility (one or more PC boards in the inverter are not compatible together) Contact GEM Energy
#482 The setup phase after the initial start-up was interrupted. Conduct an AC reset (turn it off and on again); complete start-up
#483 The voltage UDC fixed on MPP2 string is out of limits. Check MPP setting, if code continues to appear contact GEM Energy
#485 The CAN transmit buffer is full Conduct an AC reset (turn it off and on again); codes continues to appear then contact GEM Energy
#489 Permanent intermediate circuit capacitor overvoltage.  Contact GEM Energy
5 XX Fronius Inverter Error Codes
Code  Meaning What To Do?
#502 Insulation fault on the solar panel If code continues to appear, contact GEM Energy
#509 No energy has been fed into the grid in the last 24 hours Check for any other state code, if code continues to appear, contact GEM Energy
#515 Unable to communicate with filter If code continues to appear, contact GEM Energy
#516 Unable to communicate with storage unit
#517 Overheating which is causing power derating Purge cooling air openings, the fault will fix itself; if code continues to appear, contact GEM Energy
#518 Internal DSP fault If code continues to appear, contact GEM Energy
#519 Unable to communicate with storage unit
#520 No energy has been fed into the grid by MPPT1 in the past 24 hours
#522 The DC is low on string 1
#523 The DC is low in string 2
#528, #529 There is a functional incompatibility (one or more of the PC boards are not compatible) Contact GEM Energy 1300 969 471
#560 The grid frequency has become excessively high which is causing derating Code will fix itself; if the code continues to appear, contact GEM Energy
#564 There is a functional incompatibility (one or more of the PC boards are not compatible) Contact GEM Energy 1300 969 471
#566 The arc detector has been deactivated Press enter (4th button from the left).
#567 The GVDPR (grid voltage-dependent power reduction mode) is active and the inverter will operate with reduced power output If code continues to appear, contact GEM Energy
XX 6 Fronius Inverter Error Codes
Code Meaning What To Do?
#601 The CAN bus is full Contact GEM Energy 1300 969 471
#603 The AC module sensor is faulty
#604 The DC module sensor is faulty.
#607 RCMU fault Press enter (4th from the left button); if the code keeps showing, contact GEM Energy
#608 There is a functional incompatibility (one or more of the PC boards are not compatible) Update the inverters firmware, if the code continues to appear, contact GEM Energy
#609 Configuration Value of Limits Seek intervention by a Fronius-trained service engineer.
XX 7 Fronius Inverter Error Codes
Code Meaning What To Do? 
#701-716 Information about the internal processors status If code continues to appear, contact GEM Energy
#721 EEPROM has been reinitialized
#722-730 INformation about the internal processors status
#731 USB flash drive not supported Check the USB flash drive and the files, if necessary, replace.
#732 Initialisation error with USB flash drive
#733 USB flash drive not connected Check the USB flash drive and the files, if necessary, replace; contact GEM Energy
#734 Update file not recognised or missing Check the update file for issues, if necessary change file to match the device; if the code keeps showing, contact GEM Energy
#735 Update file is too old or does not match the device
#736 Write read error Check the USB flash drive and the files, if necessary, replace; If code continues to appear, contact GEM Energy
#737 Unable to open file
#738 Unable to save log file Create space on the USB flash drive; Check the USB flash drive and the files, if necessary, replace; If code continues to appear, contact GEM Energy
#740 Error in file system on USB flash drive Check the USB flash drive and the files, if necessary, replace; If code continues to appear, contact GEM Energy
#741 Error recording logging data
#743 Error during update Try the update again, check USB flash drive and replace if necessary; if the code keeps showing, contact GEM Energy
#745 The update file is corrupt Download update file retry update; if the code keeps appearing, contact GEM Energy
#746 Error while updating  Wait few minutes and try updating again; if the code keeps showing, contact GEM Energy
#751 Time lost Reset the time and date on the inverter; if the code continues to appear contact GEM Energy
#752 Communication error with real-time clock module
#753 The real-time clock module is in emergency mode Reset the time and date;if the code continues to appear contact GEM Energy
#754-755 Information about the processors status If the code continues to appear contact GEM Energy
#757 Real-time clock module hardware error Real-time clock module hardware error
#758 Real-time clock module is in emergency mode Real-time clock module is in emergency mode
#760 Internal hardware fault If the code continues to appear contact GEM Energy
#761-765 Information about the internal processors status
#766 Emergency power derating has triggered
#767 Information about the internal processors status
#768 There is a contrasting power limitation in the hardware modules
#772 Storage unit unavailable
#773 Invalid country setup
#775 The OMC power stage set unavailable Press enter (4th button from the left); if the code continues to appear contact GEM Energy
#776 The device type is invalid
#779 CAN bus transmission error Contact GEM Energy
#781-794 Information about the internal processors status If this code keeps showing, contact GEM Energy